Portable stack gas emission analyser for long time measurements of industrial combustions

O2 CO/H2 CO2 NO NO2 SO2 H2S CO CH4 C3H8 T/gas T/amb hPa

Outstanding benefits:

  • precise measuring technique by means of infrared (3-gas) and electrochemical cells (6-gas)
  • most suitable for precise low Nox measurements and other toxic gas emissions measurement according to new MCP Directive 2015/2193 for medium combustion plants with rated power <50 MW
  • all important interfaces are available, such as Ethernet (LAN), WLAN, Bluetooth, USB, RS485, 8 channel analog Outputs
  • Remote control via smartphone or tablet using VCN server via LAN/WLAN (no remote control via MRU4u app)
mgaprime-q
Basic-Equipment
  • Integrated, efficient electrical gas cooler (Peltier cooler) with automatic condensate draining pump
  • Automatic zeroing by means of 3-way solenoid valve, internal sample flow volume measurement
  • Strong, regulated sample gas pump and easy replaceable, effective PTFE filter
  • Zero gas (ambient air) inlet nozzle and separate passive VENT outlet nozzle for sample gas
  • O2 measurement included, using long-life electrochemical cell
  • Stack gas temperature measurement up to 1.200°C (optional up to 1.700°C)
  • Differential pressure or stack gas pressure +/- 100 hPa
  • Combustion air temperature up to 500°C, using adequate NiCrNi probes
  • Automatic measurement incl. data logging function
  • Large fuel type list incl. self choose fuels with user definable parameters
  • Complete combustion calculation using country specific fuel type list
  • O2 referencing (normalisation) to user settable value
  • Automatic internal test and control of soft- and hardware functions
  • Linux OS & large, high-contrast and backlit 7" (840x480) graphical display
  • Display with easy, intuitive touch panel and all measured data at one sight
  • Graphical data visualization, csv or pdf reporting file
  • Data transfer to PC over LAN Ethernet (RJ45 socket) or USB
  • 8 channel analog output 4-20mA and 4 channel analog input 4-20mA
  • Universal analogue input (AUX socket) with 0-10 V or 4-20 mA signal or K-thermocouple or RS485
  • 10.000 data of internal data storage and large data storage on external 4GB USB-stick (MRU design)
  • Universal power supply: mains 90-264 Vac/ 105 W (up to 600W with 5m heated sampling line)
  • 1 hour Li-Ion 48 Wh battery stand-by operation, with power supply for gas cooler and heated probe filter
  • Modern, rugged aluminium enclosure with rubber molded impact protection
Options

3-gas NDIR bench CO/CO2/CH4
CO 2.000ppm … 10%
CO2 0…40%
CH4 2.000ppm … 4%

3-Gas NDIR bench CO/CO2/C3H8
CO 2.000ppm…10%
CO2 0…40%
C3H8 2.000ppm…20.000ppm

CO-measurement (H2 compensated)
0…10.000, overload up to 20.000ppm

CO(very high)-measurement
0…4,00, overload up to 10,00%

NO-measurement
0…1.000, overload up to 5.000 ppm

NO2-measurement
0…200 overload up to 1.000 ppm

SO2-measurement
0…2.000, overload up to 5.000 ppm

H2S-measurement
0…500, overload up to 2.000 ppm

3-gas NDIR bench CO/CO2/CH4
CO 2.000ppm … 10%
CO2 0…40%
CH4 2.000ppm … 4%

RS 485 interface
with modbus RTU protocol for wired far distance data transfer

Additional LiIon battery 12V/48Wh
for additional 1h mains free stand-by operation

USB to Bluetooth converter set
for wireless data transfer

Accessories

“Pelicase” style transport case
suitable for flight transportation

WLAN/USB printer
with LiIon battery, 80mm paper width and battery charger

Combustion air temperature probe, 300 mm
w/ PTFE cone and 2,7m cable

Pitot tube, L-type, with temperature measurement
100 x Ø 3mm

Darcy tubes, Type S
for flow velocity measurement, incl. temperature measurement, 300, 1.000 or 1.500mm length

Gas sampling probe handle Type F
for exchangeable tubes

Exchangeable probe tube Type F, 180 or 300mm
from 300 mm up to 2.000 mm length

Sintered metal filter 3µ
for F-type gas sampling probe

Glass wool filter material
1 carton=50x30g for 750 filtering processes

Printer paper 80mm width
thermo paper, pack of 5 rolls

Service- and cleaning kit VARIOluxx
filter, silicone grease, air bulb, cloth, seals, etc.

Technical Data

Measuring range

O2 (electrochemical) 0 … 25,00 %
CO (H2 compensated) (electrochemical) 0 … 10.000 ppm / overload up to 20.000 ppm
CO2 (infrared) 0 … 5,00 % / overload up to 40,00 %
NO (electrochemical) 0 … 1.000 ppm / overload up to 5.000 ppm
NO2 (electrochemical) 0 … 200 ppm / overload up to 1.000 ppm
SO2 low (electrochemical) 0 … 100,0 ppm
SO2 (electrochemical) 0 … 2.000 ppm / overload up to 5.000 ppm
H2S (electrochemical) 0 … 2.000 ppm / overload up to 5.000 ppm
CO low (electrochemical) 0 … 500,0 ppm
CO very high (electrochemical) 0 … 2,00 % / overload up to 10,00 %
CO (infrared) 0 … 3.000 ppm / overload up to 30.000 ppm
CO (infrared) 0 … 1,00 % / overload up to 10,00 %
HC (CH4) (infrared) 0 … 3.000 / overload up to 10.000 ppm
HC (C3H8) (infrared) 0 … 1.000 ppm / overload up to 10.000 ppm
HC (CH4) (infrared) 0 … 1,00 % / overload up to 4,00 %
NO low (electrochemical) 0 … 300,0 ppm
NO2 low (electrochemical) 0 … 100,0 %
H2S low (electrochemical) 0…50 ppm / overload up to 500 ppm
Fluegas temperature 0 … 1.200 °C
Combustion air temperature 0 … 500 °C
Ambient air temperature 0 .. 100 °C
Differential pressure -120 … + 120 hPa
Flow measurement 3 … 100 m/s

Dimensions and other data

Display 7“ TFT (800 x 480 px) colour display, backlit, with touch operation
Dimensions (W x H x D) 430 x 290 x 150 mm
Weight appr. 7,5 kg (with minimal configuration)
Operating system LINUX
Data storage 10.000 data sets internal and external USB-Stick
Interfaces Ethernet, Bluetooth, WLAN, RS485
Operating temperature +5 … +50 °C ; RH up to 95 % not condensing
Storage temperature -20 … +50 °C
Internal power supply Li-Ion , 48 Wh, for appr. 1 hr „stand-by“ (optional additional battery, 48 Wh Li-Ion)
External power supply 86 … 265 Vac / 47 … 63 Hz / 105 W (up to 600 W with heated sampling line)
Protection IP20 (or IP42 inside transport case)

Acest site folosește cookie-uri pentru a îmbunătăți experiența dumneavoastră. Informațiile stocate sub formă de cookie-uri nu vă identifică direct, dar contribuie la personalizarea experienței dumneavoastră pe acest site. Aveți controlul asupra setărilor cookie-urilor - puteți afla mai multe și să le schimbați dând click pe categoriile de mai jos. Blocarea anumitor cookie-uri poate afecta funcționalitatea site-ului și serviciile noastre.

Close Popup
Privacy Settings saved!
Setările de confidențialitate

Când vizitați orice site web, acesta poate stoca sau prelua informații din browserul dvs., mai ales sub formă de cookie-uri. Controlați-vă serviciile personale de cookie-uri aici.

These cookies are necessary for the website to function and cannot be switched off in our systems.

Technical Cookies
In order to use this website we use the following technically required cookies
  • wordpress_test_cookie
  • wordpress_logged_in_
  • wordpress_sec

Refuzați toate serviciile
Salvați
Acceptați toate Serviciile
Open Privacy settings