Gasmet CMM

Gasmet Continous Mercury Monitoring System (CMM)

CMM AutoQAL & CMM Continuous Mercury Monitoring Systems

Key benefits

  • Certified and fully automatic system
  • Future proof for declining emission limits
  • Easy to operate & low-cost of ownership
  • Robust design for challenging conditions
  • Minimized downtime due to fast and easy maintenance and automatic QAL3 test (CMM AutoQAL)
cmm-autoqal-01

Continuous Mercury Monitoring systems, the CMM and CMM AutoQAL, are TÜV and MCERTS certified solutions for continuous mercury monitoring from hot, wet and corrosive gas streams of industrial processes, such as waste incineration, cement production and powerplants. Gasmet offers a full CMM solution package which consists of a system, lifetime service and support, documentation and training, and our expertise.

Mercury Monitoring with Automatic QAL3 Validation Tool

CMM AutoQAL has a certified validation tool with the possibility to do both Hg0 and HgCl2 checks. This means that there is no need for an external gas generator for QAL3 operations. This leads to saved time and money, making the system more cost-efficient with minimal operating costs. Additional manual checks are possible if needed, all done with one button to ensure user-friendliness. Other benefits:

  • No need for additional QAL3 equipment
  • Software giving immediate results: Pass / Fail

Technical Highlights

  • Future-proof with the lowest measuring range in the world 0—5 µg/m³ (EN 15267)
  • Real-time results with fast response time, <120s > Excellent annual availability of 99%
  • The highest sensitivity in the market with the detection limit of 0.02 µg/m³
  • Highest certified range up to 1000 µg/m³ and measures even higher concentration peaks
  • Measures total Hg ensuring zero Hg-derivates being undetected
  • 3-month maintenance interval (CMM)

Emissions monitoring handbook

Download our free handbook and receive an overall picture of the (European) requirements, regulatory framework, practicalities, and solutions in gas emissions monitoring. Applications include large industrial plants requiring continuous emissions monitoring:

  • Waste incineration (WI) / waste-to-energy (WtE)
  • Co-incineration of waste (co-WI)
  • Large combustion plants (LCP)
  • Chemical plants and related industries
emissions-monitoring-handbook-mockup

Innovative Gasmet design
Mercury can be a challenging component to measure for many technologies and systems. Thanks to the CVAF (Cold Vapor Atomic Fluorescence ) technology and nitrogen dilution, reliable and extremely accurate results are achieved, without interferences from other gases. The system is fully automatic, and the automatic Hg0 calibrations are done at user-defined intervals.

Minimized downtime
Modular design means individual parts can be removed. This minimizes system downtime and makes the maintenance procedure easy and cost-effective. System settings can be accessed from the easy-to-use Mercury Analyzer User Interface (MAUI), created by Gasmet’s specialists.

Futureproof solution for declining emission limits
CMM AutoQAL is a futureproof solution fulfilling the certified range according to ELVs (emission limit value). According to EN 15267-3, the minimum accepted certified range WI (waste incineration) of a system shall not be more than 1.5 times the daily ELV and LCP (large combustion plants) 2.5 times daily ELV. The system has the lowest measuring range in the world, 0—5 µg/m³ (EN 15267) (max certified range is 1000 µg/m³ & even higher concentration peaks can be measured without any hardware changes).

Thermal converter ensures a long lifetime
As mercury does not always occur in its chemical element form (Hg0), characteristics of mercury are considered, and an integrated thermal converter converts all mercury compounds to elemental mercury to measure total gaseous mercury. This ensures that none of the Hg-derivatives are left undetected. It has a longer lifetime compared to traditional catalytic converters, which leads to reduced downtime and costs.

Peace of mind with continuous measurement
Continuous measurement provides better control of emissions than periodic measurement. Hg concentrations in industrial emissions are usually extremely low but can suddenly increase temporarily to very high levels depending on the fuel or incinerated waste. Operators can react to the concentration changes and optimize their processes if needed.

CMM systems overview
The system consists of a dilution probe, heated sample line, CMM cabinet, mercury analyzer and Gasmet test gas generator (for Hg0). A heated dilution probe with a two-stage blowback system ensures the durability and low maintenance of the system even in demanding conditions.

Gasmet’s solution package for mercury monitoring

Buy with confidence
As your potential emission monitoring partner, we offer a complete solution for your specific emission monitoring needs. Our very own technology ensures long-term reliability, ease of use and full compliance.

Mutual trust and years of expertise

We strive to provide a smooth partnership for every step. We walk you through the whole process from consultation to commissioning of the system, and all the way to service and support.

Local support

Our global multi-disciplined teams and vast distributor network ensure that professional and fast service and support are available locally.

Gasmet also meets your emission measurement needs for hundreds of other emissions as well as dioxins and furans with complete solutions.

    Acest site folosește cookie-uri pentru a îmbunătăți experiența dumneavoastră. Informațiile stocate sub formă de cookie-uri nu vă identifică direct, dar contribuie la personalizarea experienței dumneavoastră pe acest site. Aveți controlul asupra setărilor cookie-urilor - puteți afla mai multe și să le schimbați dând click pe categoriile de mai jos. Blocarea anumitor cookie-uri poate afecta funcționalitatea site-ului și serviciile noastre.

    Close Popup
    Privacy Settings saved!
    Setările de confidențialitate

    Când vizitați orice site web, acesta poate stoca sau prelua informații din browserul dvs., mai ales sub formă de cookie-uri. Controlați-vă serviciile personale de cookie-uri aici.

    These cookies are necessary for the website to function and cannot be switched off in our systems.

    Technical Cookies
    In order to use this website we use the following technically required cookies
    • wordpress_test_cookie
    • wordpress_logged_in_
    • wordpress_sec

    Refuzați toate serviciile
    Salvați
    Acceptați toate Serviciile
    Open Privacy settings